With 20 L/min, the CELENO Nitrogen range provides a High Purity Nitrogen solution for GC x GC instrument with Cryogen. The generator has very low dew point to work with cryogenic applications without any freezing.
The CELENO is available without or with integrated oil free air compressor using the Energy Saving Technology mode (EST). It is extremely compact and quiet in operation. The generator is controlled using the latest in color touch screen technology to display the process in real time, inlet / outlet pressure, N2 Flow and status of the system with remote access for diagnostic control.
Utilizing Advanced technology PSA of separating Nitrogen and Oxygen to produce high quality Nitrogen gas on demand 24/7.
Advantages product
INCREASED LABORATORY EFFICIENCY
A constant, uninterrupted gas supply of guaranteed purity
eliminates interruptions of analyses to change cylinders and
reduces the amount of instrument re-calibrations required.
IMPROVED ECONOMY
Pure nitrogen gas produced as standard.
IMPROVED SAFETY
Nitrogen produced at low pressure and ambient temperature
removes the need for high pressure cylinders.
SECURITY OF SUPPLY
Integral oil free air compressor as an option guarantees
continuous gas supply, independent of in house compressed
air supply.
SIMPLE INSTALLATION
Gas generators can be installed in the laboratory, on or
under a bench, eliminating the need for long gas lines from
cylinders secured elsewhere.
Characteristics
- Intelligent color touch screen to provide simple and user friendly management of all functions of the unit
- Fully regenerative PSA technology
- Without or with integral oil free air compressor
- Quiet thanks to the Soundproofed compressor box and anti-vibration features
- Low N2 dewpoint < -60°C (< -76°F)
- Auto start
- Fast start-up purity < 60 min
- Audible alarm display and Visual maintenance indication with history log Outlet flow indicat
- Outlet flow indicator
- Energy Saving Technology (EST):
- Switch off the compressor when gas supply is not required
- Allowing low energy consumption and increasing durability of the compressor - Remote PC monitoring and diagnostic analysis via USB to interface the unit with customer’s PC software (allow to carry out checks and maintenance effectively, only via a remote connection)
- Compact design
- Fit with wheels
Specifications
Models | CELENO.20 | |
Compressor | 0 (Without) | 1(With) |
GENERALS INFORMATIONS | ||
Max Nitrogen Flow rate | 20 L/min | |
Max Nitrogen outlet pressure | 6 bar (87 psi) | |
Nitrogen purity* | > 99.5% (< 0.5% O2) | |
Nitrogen dewpoint | < -60°C (< -76°F) | |
Particles | 0.01 μ | |
Inlet Air flow required @ 8 bar (116 psi) max | 70 L/min | N /A |
Min Inlet Air quality | ISO8573 – 1:2010 1.4.1 | N/A |
Touch screen | Touch screen (operating parameters, system status, alarms) with LED indicators(Power on/off; ready or errors) | |
Max Relative Humidity | 80% RH @ 25°C (77°F) | |
Temperature range | From 5 – 25°C (41 – 77°F) | |
Max Altitude | 3000 Meters | |
Noise level @ 1M | 25 dB (A) | 52 dB (A) |
Dimensions (W x H x D) |
47.5 x 66.2 x 79 cm(18.7″ x 26″ x 31″) | |
Weight (kg/lbs) | 91 / 200 | 118 / 260 |
Electrical supply |
220 – 240 V ac / 1 ph / 50 – 60 Hz | |
110 – 120 V ac / 1 ph / 50 – 60 Hz | ||
Fuse | 10A | |
CONNECTIONS | ||
Nitrogen outlet | 1/4″ GF | |
COMMUNICATION | ||
USB/PC Control | In series |